Details B1 and B2 halls INTERIOR:

  • total usable area: 27.300 square meters
  • B1 and B2 pavilions are joined by a connecting body - B3, forming a common structure
  • the pavilions are equipped with air conditioning, 3 functional zones / pavilion
  • the resistance structure is composed of octagonal metal poles and metal trusses, all fire-protected, with main openings of 12 x 42 m
  • general zone lighting with LED luminaires
  • fire safety authorization issued by ISU

Details of the B1 and B2 EXTERIOR pavilions:

  • technical spaces (2 trafo posts)
  • generating set
  • general electrical panels
  • fire alarm panel
  • ACS rooms

Pavilion B1

General technical characteristics:

  • total usable area: 12.067 square meters
  • exhibition area: 11.750 square meters
  • height: ground floor
  • height under the metal truss - lattice girder: 10.56 m
  • total height: 14.17 m
  • permissible floor weight: max. 5000 kg/sq.m
  • freight/pavilion doors: 4
  • Visitor entrance areas (including evacuation): 9
  • Underground escape routes (underground escape chutes): 3
  • available connections: electricity, water/sewerage, data-voice communication network
  • concrete floor finished by helicopter process
  • exterior walls in sandwich panels finished in white on the inside
  • Ceiling load: up to four dummy loads at 500 kg each (winter scenario) or 800 kg each (summer scenario) can be applied to the purlins; up to six dummy loads at 800 kg each (winter scenario) or 1200 kg each (summer scenario) can be applied to the bottom sole of the trusses

Pavilion B2

General technical characteristics:

  • total usable area: 15.366 square meters
  • exhibition area: 15.222 square meters
  • height: ground floor
  • height under the metal truss - lattice girder: 10.56 m
  • total height: 14.17 m
  • permissible floor weight: max. 5000 kg/sq.m
  • cargo doors/pavilion: 4
  • Visitor entrance areas (including evacuation): 9
  • Underground escape routes (underground escape chutes): 3
  • available connections: electricity, water/sewerage, data-voice communication network
  • concrete floor finished by helicopter process
  • exterior walls in sandwich panels finished in white on the inside
  • Ceiling load: up to four dummy loads at 500 kg each (winter scenario) or 800 kg each (summer scenario) can be applied to the purlins; up to six dummy loads at 800 kg each (winter scenario) or 1200 kg each (summer scenario) can be applied to the bottom sole of the trusses

Pavilion B3

The parter:

  • main entrance hall / visitors access - 1420 sq.m, tiled floor
  • info point/ official openings area
  • Café -155 square meters (capacity 75 seats)
  • press corner with 8 workstations
  • technical spaces for supervision and control of the air conditioning and signaling system in case of need

Upstairs:

  • the multifunctional pavilion B3 has 2 rooms upstairs, suitable for conferences, launches and other adjacent events: 1300 square meters; equipped with projection screens, sound and air conditioning; depending on the requests, they can be compartmentalized so that the capacity can be adapted to the requirements
  • welcome lounge area
  • built-in wardrobe
  • own sanitary facilities

Basement:

  • multi-facility toilets, including 'mother and baby' and disabled people
  • non-slip flooring